7 | This document is **WORK IN PROGRESS**. |
||
8 | |||
9 | h2. Introduction |
||
10 | |||
11 | This article describes the ungleich storage architecture that is based on ceph. It describes our architecture as well maintenance commands. Required for |
||
12 | |||
13 | h2. Communication guide |
||
14 | |||
15 | Usually when disks fails no customer communication is necessary, as it is automatically compensated/rebalanced by ceph. However in case multiple disk failures happen at the same time, I/O speed might be reduced and thus customer experience impacted. |
||
16 | |||
17 | For this reason communicate whenever I/O recovery settings are temporarily tuned. |
||
18 | |||
19 | 2 | Nico Schottelius | h2. Adding a new disk/ssd to the ceph cluster |
20 | |||
21 | h3. For Dell servers |
||
22 | |||
23 | First find the disk and then add it to the operating system |
||
24 | |||
25 | <pre> |
||
26 | megacli -PDList -aALL | grep -B16 -i unconfigur |
||
27 | |||
28 | # Sample output: |
||
29 | [19:46:50] server7.place6:~# megacli -PDList -aALL | grep -B16 -i unconfigur |
||
30 | Enclosure Device ID: N/A |
||
31 | Slot Number: 0 |
||
32 | Enclosure position: N/A |
||
33 | Device Id: 0 |
||
34 | WWN: 0000000000000000 |
||
35 | Sequence Number: 1 |
||
36 | Media Error Count: 0 |
||
37 | Other Error Count: 0 |
||
38 | Predictive Failure Count: 0 |
||
39 | Last Predictive Failure Event Seq Number: 0 |
||
40 | PD Type: SATA |
||
41 | |||
42 | Raw Size: 894.252 GB [0x6fc81ab0 Sectors] |
||
43 | Non Coerced Size: 893.752 GB [0x6fb81ab0 Sectors] |
||
44 | Coerced Size: 893.75 GB [0x6fb80000 Sectors] |
||
45 | Sector Size: 0 |
||
46 | Firmware state: Unconfigured(good), Spun Up |
||
47 | </pre> |
||
48 | |||
49 | Then add the disk to the OS: |
||
50 | |||
51 | <pre> |
||
52 | megacli -CfgLdAdd -r0 [enclosure:slot] -aX |
||
53 | |||
54 | # Sample call, if enclosure and slot are KNOWN (aka not N/A) |
||
55 | megacli -CfgLdAdd -r0 [32:0] -a0 |
||
56 | |||
57 | # Sample call, if enclosure is N/A |
||
58 | megacli -CfgLdAdd -r0 [:0] -a0 |
||
59 | </pre> |
||
60 | |||
61 | 1 | Nico Schottelius | |
62 | h2. Moving a disk/ssd to another server |
||
63 | |||
64 | h2. Removing a disk/ssd |
||
65 | |||
66 | h2. Handling DOWN osds with filesystem errors |
||
67 | |||
68 | If an email arrives with the subject "monit alert -- Does not exist osd.XX-whoami", the filesystem of an OSD cannot be read anymore. It is very highly likely that the disk / ssd is broken. Steps that need to be done: |
||
69 | |||
70 | * Login to any ceph monitor (cephX.placeY.ungleich.ch) |
||
71 | * Check **ceph -s**, find host using **ceph osd tree** |
||
72 | * Login to the affected host |
||
73 | * Run the following commands: |
||
74 | ** ls /var/lib/ceph/osd/ceph-XX |
||
75 | ** dmesg |
||
76 | * Create a new ticket in the datacenter light project |
||
77 | ** Subject: "Replace broken OSD.XX on serverX.placeY.ungleich.ch" |
||
78 | ** Add (partial) output of above commands |
||
79 | ** Use /opt/ungleich-tools/ceph-osd-stop-remove-permanently XX, where XX is the osd id, to remove the disk from the cluster |
||
80 | ** Remove the physical disk from the host, checkout if there is warranty on it and if yes |
||
81 | *** Create a short letter to the vendor, including technical details a from above |
||
82 | *** Record when you sent it in |
||
83 | *** Put ticket into status waiting |
||
84 | ** If there is no warranty, dispose it |
||
85 | |||
86 | |||
87 | |||
88 | h2. Change ceph speed for i/o recovery |
||
89 | |||
90 | By default we want to keep I/O recovery traffic low to not impact customer experience. However when multiple disks fail at the same point, we might want to prioritise recover for data safety over performance. |
||
91 | |||
92 | The default configuration on our servers contains: |
||
93 | |||
94 | <pre> |
||
95 | [osd] |
||
96 | osd max backfills = 1 |
||
97 | osd recovery max active = 1 |
||
98 | osd recovery op priority = 2 |
||
99 | </pre> |
||
100 | |||
101 | The important settings are *osd max backfills* and *osd recovery max active*, the priority is always kept low so that regular I/O has priority. |
||
102 | |||
103 | To adjust the number of backfills *per osd* and to change the *number of threads* used for recovery, we can use on any node with the admin keyring: |
||
104 | |||
105 | <pre> |
||
106 | ceph tell osd.* injectargs '--osd-max-backfills Y' |
||
107 | ceph tell osd.* injectargs '--osd-recovery-max-active X' |
||
108 | </pre> |
||
109 | |||
110 | where Y and X are the values that we want to use. Experience shows that Y=5 and X=5 doubles to triples the recovery performance, whereas X=10 and Y=10 increases recovery performance 5 times. |
||
111 | |||
112 | h2. Debug scrub errors / inconsistent pg message |
||
113 | |||
114 | From time to time disks don't save what they are told to save. Ceph scrubbing detects these errors and switches to HEALTH_ERR. Use *ceph health detail* to find out which placement groups (*pgs*) are affected. Usually a *ceph pg repair <number> fixes the problem. |
||
115 | |||
116 | If this does not help, consult https://ceph.com/geen-categorie/ceph-manually-repair-object/. |