Setting up a newly arrived Mikrotik switch¶
This part is specific for mikrotik-crs326 devices and should
After arriving within 1 work day do:
- Unpack
- Find out which name the switch should have
- go to https://netbox.ungleich.ch
- search for crs326
- identify the last used number
- Create a new device
- go to devices
- devices
- add
- name: "mikrotik-crs326-XX"
- device-role: a device role
- device-type: CRS326
- serial-number: <from the device>
- site: placeX -
- create
- Add a physical label with its name
- Do not continue before you have done that!
- configure your notebook with the ipv4 address 192.168.88.23/24
- connect to the crs326:
ssh admin@192.168.88.1
- Configure the switch
- Set identity:
/system identity set name=mikrotik-crs326-XX
# use the correct name - Set password:
/user set admin password=
# use the password for mikrotik in the place that you are, use password store - Enable IPv6:
/system package enable ipv6
- Reboot so that IPv6 is enabled:
/system reboot
- Add a place indendent, unrouted IPv6 address:
/ipv6 address add eui-64=yes advertise=no interface=bridge address=2a0a:e5c0:1:c::/64
- Get the assigned IPv6 address:
/ipv6 address print
- Disconnect from the switch
- Set identity:
- Assign your notebook the IPv6 address 2a0a:e5c0:1:c::23/64
- Connect to the switch via IPv6
- Remove the IPv4 address 192.168.88.1 to avoid collisions with other switches:
/ip address remove numbers=0
- Verify:
/ip address print
- Verify:
- Remove the IPv4 address 192.168.88.1 to avoid collisions with other switches:
- Verify / update entries in netbox:
- Verify that the serial number is correct:
:put [ /system routerboard get serial-number ]
- Netbox
- go to the ipv6 prefix https://netbox.ungleich.ch/ipam/prefixes/216/
- create a new ipv6 address
- set the DNS name to mikrotik-crs326-XX
- role = loopback
- go to the ipv6 prefix https://netbox.ungleich.ch/ipam/prefixes/216/
- Verify that the serial number is correct: